Add/Review Content
Upload Probes
The SureSelect RNA advanced wizard allows you to upload your own probe sequences. You may want to use this method for adding content if you have a set of probes that were designed with your own algorithms or were designed for a species that SureDesign does not support.
This method is also useful if you want to make edits to the probes in an existing custom or catalog design. You can download the probes from the existing design, make your edits, and then upload the edited probes.
When you select to add content using the Upload Probes method, you provide a file containing the probe information, including sequences, and submit the file to SureDesign as a probe upload job. SureDesign uploads the probes and saves them as a probegroup. You receive an e-mail from Agilent SureDesign when the upload process is complete.
NOTE Prepare your probe upload file before you begin this step of the wizard. The maximum number of probes permitted per file is 363,000, including replicates. The file must be a tab-delimited text file (*.txt format) in a 4-column or 7-column format. For upload purposes, create a compressed (*.zip format) version of the text file. The compressed file must be no larger than 20 MB. Click here for further information on the file format requirements.
Complete the fields and selections in this step to designate the file you want to upload and set some of the parameters for the probes.
File Name
Click Browse to select the probe upload file (in *.zip format). Alternatively, if you know the file path for the file, you can type it directly into the File Name field.
Probe Precedence
The Reuse Existing approach is used when SureDesign finds a probe in your uploaded file with the same probe ID as an existing probe.
· Reuse Existing - SureDesign keeps the existing probe and adds that probe to your design. SureDesign does not overwrite the existing probe with the sequence or annotation information from the uploaded file.
Boosting
SureDesign can boost the number of copies for any GC-rich probes in the new probegroup. Boosting these probes can potentially improve their ability to capture target genomic fragments.
In the Boosting drop-down list, select one of the options described below, or leave the default option in place. The default option is the one Agilent recommends, and it is determined by the hybridization type selected in the Define Design step.
· Optimized Performance XT – This option is the default when the hybridization type is set to Overnight or Not Specified. This boosting algorithm is specifically optimized for the hybridization conditions in the SureSelect XT library preparation protocol to deliver optimal sequencing uniformity and read depth across the full range of GC content percentages.
· Optimized Performance XT HS2 - This option is the default when the hybridization type is set to 90 minutes or Not specified. This boosting algorithm is specifically optimized for the hybridization conditions in the SureSelect XT HS2 library preparation protocol to deliver optimal sequencing uniformity and read depth across the full range of GC content percentages.
· User Provided - SureDesign uses the Replication column in the uploaded file to determine how many times a probe will be replicated in the library.
To submit the selected file for upload:
When you are ready to upload the file, click
Next.
A message box opens indicating the e-mail address where Agilent will
contact you when SureDesign has finished uploading your probes. If
desired, you can enter additional e-mail addresses into the provided
field in the message box.
Click OK
in the message box to submit the file.
SureDesign begins the process of uploading your probes. The program
first scans the Probe Upload file for formatting errors. If it detects
a formatting error, SureDesign notifies you by e-mail. If it does
not detect any formatting errors, SureDesign uploads the probes into
your SureDesign account.
The wizard takes you to the Add/Review
Content screen. The new probegroup appears in the Probegroup Summary
table. The # Targets column of the table lists Processing
until the probe upload job is complete. Click the refresh icon
to see updates to this column.
You receive an e-mail from Agilent SureDesign notifying you when your
job is complete. In order to finalize the design, you must wait until
your probe upload job is complete.
Click Close Design Wizard to return to the SureDesign Home page. You will see your Design listed in the Designs: In Progress table.