The functionality described in this
topic is only available when you mark Show
Advanced Options.
Add/Review Content
Upload Probes
The ChIP advanced wizard allows you to upload your own probe sequences. You may want to use this method for adding content if you have a set of probes that were designed with your own algorithms.
This method is also useful if you want to make edits to the probes in an existing custom or catalog design. You can download the probes from the existing design, make your edits, and then upload the edited probes.
When you select to add content using the Upload Probes method, you provide a file containing the probe information, including sequences, and submit the file to SureDesign as a probe upload job. SureDesign uploads the probes and saves them as a probegroup. You receive an e-mail from Agilent SureDesign when the upload process is complete.
NOTE Prepare your probe upload file before you begin this step of the wizard. The file must be a tab-delimited text file (*.txt format) in a 2-column or 6-column format. For upload purposes, create a compressed (*.zip format) version of the text file. Click here for further information on the file format requirements.
Complete the fields and selections in this step to designate the file you want to upload and set some of the parameters for the probes.
Probegroup Name
Type a name for the new probegroup. Permitted characters are alphanumeric characters (A-Z, a-z, 0-9), spaces, underscores (_), periods (.), and hyphens (-). The name must start with an alphanumeric character.
File Name
Click Browse to select the probe upload file (in *.zip format). Alternatively, if you know the file path for the file, you can type it directly into the File Name field.
Templates
The available formats for the probe upload file are the 2-Column and 6-Column formats. Click the links to view examples of each.
Probe Precedence
Specify what you want SureDesign to do if it finds a probe in your uploaded file with the same probe ID as an existing probe.
· Reuse Existing - SureDesign keeps the existing probe and adds that probe to your design. SureDesign does not overwrite the existing probe with the sequence or annotation information from the uploaded file.
· Overwrite - SureDesign overwrites the existing probe with the annotation information from the uploaded file, including the genomic coordinates, but it does not overwrite the probe sequence. This option is useful if you want to update the annotation information on your existing probes.
To submit the selected file for upload:
When you are ready to upload the file, click
Next.
A message box opens indicating the e-mail address where Agilent will
contact you when SureDesign has finished uploading your probes. If
desired, you can enter additional e-mail addresses into the provided
field in the message box.
Click OK
in the message box to submit the file.
SureDesign begins the process of uploading your probes. The program
first scans the Probe Upload file for formatting errors. If it detects
a formatting error, SureDesign notifies you by e-mail. If it does
not detect any formatting errors, SureDesign uploads the probes into
your SureDesign account.
The wizard takes you to the Add/Review
Content screen. The new probegroup appears in the Probegroup Summary
table. The # Targets column of the table lists Processing
until the probe upload job is complete. Click the refresh icon
to see updates to this column.
You receive an e-mail from Agilent SureDesign notifying you when your
job is complete. In order to finalize the design, you must wait until
your probe upload job is complete.