Create library from existing bait groups (wizard) |
|
If you have bait groups that you want to use to create a new library, you can use this wizard to lead you through the process. This wizard is available for the SureSelect Target Enrichment and SureSelect RNA Enrichment application types, and it is especially useful if you know the specific bait groups that you want to include in your library. If you need to use more sophisticated bait group search criteria, use the procedure described in Create library from bait group search results.
This help topic contains the following sections:
Click the Workspace tab, or enter a collaboration.
Set the application type to SureSelect Target Enrichment or SureSelect RNA Enrichment.
Click Home.
On your individual or collaboration workspace home page, in the Library Wizards pane, select Create Library from Existing Bait Group(s).
Click Next.
The first step of the wizard, Select
Species, appears in a new window.
In this step of the wizard, you select the species that best represents the content of the library you want to create.
In Select Species, these parameters appear:
Parameter |
Instructions/Details |
Library Category |
(Read-only, SureSelect RNA Enrichment application type only) eArray supports RNA Capture libraries, which retrieve specific RNA species from a pool of RNAs. |
Species |
Select the species that best represents the content of the library that you want to create. |
Click Next.
The next step of the wizard, Define
Library, appears.
In this step of the wizard, you define general attributes of the library, such as its name and location.
Enter the following parameters. All are required unless otherwise noted.
Parameter |
Instructions/Details |
Library Type |
Select between creating a Normal library and a Supplemental library. A supplemental library is intended to be paired with an Agilent catalog library to create a combined library. Supplemental libraries can contain up to 57,750 baits, including the required Agilent quality control baits. A normal library is not paired with an Agilent catalog library, but if desired, it can later be used to create a combined library using the Combine Libraries wizard. If you select Supplemental as the library type, you need to then make additional selections:
|
Library Details |
|
Library Name |
Type a name for the library. eArray uses this name as one of the search keys for libraries, and as a way to refer to it in search results, lists, and the like. |
Length |
eArray supports a bait length of 120 nucleotides. All baits in a library have the same length. |
Folder |
Select a location for your new library. The folders to which you have access appear in the list. |
Species |
(Read-only) Reflects the species that you selected in the previous step of the wizard. |
Library Size |
(Read-only) Currently, eArray supports a library size of 1 X 55K, which can accommodate up to 57,750 baits, including the required Agilent quality control baits. For the SureSelect Target Enrichment application type, click Show Details to see additional information about available features and the control grid that will be applied. In addition, for this application type, eArray automatically creates a library set when you design a library that contains more than 57,750 baits. |
Control Grid |
(SureSelect Target Enrichment application type only) eArray automatically selects an appropriate control grid for the library. The name of the Agilent control grid appears as a link. To view details about the control grid, click the link. To select an alternate control grid, if
one is available, click Agilent has two control grids: Hs and Generic. If you select H. sapiens as the species, eArray automatically selects the Hs control grid. Otherwise eArray selects the Generic control grid. These small groups do not affect your capture and are for Agilent QC purposes. For the bait groups that you add, generally users designate all of them with a control type of biological. If you have a control group planned (and you want to, for example, hybridize spiked-in DNA to those baits), then you could designate the group with a control type of Positive. This designation does not have any special effect on the synthesis of the library. Control baits are not listed in the BED file. |
Show Other Library Details (The properties below appear if you mark Show Other Library Details.) |
|
Description |
(Optional) Type a brief description for the library. |
Keywords |
(Optional) Type search keywords to associate with the library, separated by commas. Keywords can help you search for the library. |
Attachment |
(Optional) Attachments are files or links that are related your library. Attached files can be up to 32 MB in size. To add one or more attachments, follow these steps:
Name – Type a name for the attachment. This name becomes the link that you click to access the attachment. Type – Select the desired type of attachment from the list. An attachment can be either a file or a URL. Locale – Select the appropriate locale from the list. eArray uses this option to select content that has been localized for your region, when it is available. File – (Available only if you selected File for the type of attachment) Click Browse. Select the desired attachment in the dialog box that appears, then click Open. URL – (Available only if you selected URL for the type of attachment) Type the full URL of the Internet resource, including the protocol specifier. For example, http://www.agilent.com.
|
Comments |
(Optional) Type comments to include with the library. |
Click Next.
The next step of the wizard, Layout
Baits, appears.
In this step of the wizard, you add and configure the bait group(s) that you want to include in your library.
Use the tasks in the table below to select bait groups for your library. As you add and configure bait groups in the library, the Library Statistics pane reflects your choices. For more information about these statistics, see Calculated library statistics.
Task |
Instructions/Details |
Bait Group Details |
|
To add bait group(s) to your library:
|
|
View a bait group |
In the Bait Group Name column, the names of bait groups in the library appear as links. Click the desired link to view details about the bait group. The View Bait Group page appears in a new window. For details about this page, see View bait group. |
Remove bait group |
To remove a bait group from the library:
|
Change number of copies of bait group |
In the Replicate column, next to the desired bait group, type the number of copies of the bait group you want to include in the library.
|
Change bait boosting preference |
Bait boosting increases the representation of "orphan" and GC-rich baits within the library by an Agilent-defined factor. Agilent applies bait boosting to libraries by default.
To change the bait boosting preference for the library
A dialog box asks if you are sure you want to change your boosting preference.
|
Note:
(SureSelect Target Enrichment application type only) Currently, eArray
supports the 1 X 55K library size, which can accommodate up to 57,750
baits. If you design a custom library that contains more than 57,750
baits, eArray automatically creates a library
set, which distributes the requested baits evenly among multiple
libraries. Library sets are handled as a single entity. You cannot
separately work with or order the individual libraries in a library
set. For details, see Library
sets.
When a library set is needed to accommodate all of the requested baits
in the library, eArray automatically marks the Enable
Library Set check box. A dialog box tells you that multiple
libraries are needed to cover the design. If you do not want to create
a library set, you can remove bait groups from the library or decrease
the number of copies of one or more bait groups until the library
contains 57,750 baits or fewer.
eArray automatically enables and disables library sets as needed. You
cannot manually mark or clear the Enable Library Set check box.
Click Next.
The next step of the wizard appears.
In this step, you save your library with a specific status.
In How do you want to save and create your library?, select one of these options:
Draft – eArray saves the library with a status of Draft. Only you can edit the library.
Review – eArray saves the library with a status of Review. The users in your workgroup can edit the library and save versions of it.
Complete – eArray saves the library with a status of Complete. The library can be submitted to Agilent Manufacturing, and no one can edit it.
Submit – eArray saves the library with a status of Submitted, and submits the library to Agilent Manufacturing. If you select this option, you must also click Design Checklist, then read and mark all of the items that appear. Later, you can request a quote or order the library.
Click Save.
eArray creates and saves your library. A success message appears.
Click Close.
Another success message appears.
Click Close.
See also