Create mutagenesis library from existing oligo sets (wizard) |
|
Mutagenesis libraries are collections of DNA oligonucleotides (oligos) that can be used to create variant forms of targeted proteins for a variety of experimental applications (see Learn about mutagenic oligos and mutagenesis libraries). This wizard leads you through the creation of a mutagenesis library based on oligo sets that already exist in your eArray account. You can also create mutagenesis libraries in other ways. See Ways to create mutagenesis libraries.
Before you can use this wizard, you must have one or more mutagenesis oligo sets accessible to you within eArray. To see all of the oligo sets that are available to you, do an oligo set search and leave the search term blank. To create oligo sets, you can use the Create Mutagenesis Oligo Sets wizard, or the Create Mutagenesis Library from Target Sequence wizard.
The wizard leads you through several steps, summarized below. For detailed instructions for a specific step, click its name.
Step 1 – Define Library – In this step, you enter the name of the library and optional descriptive information.
Step 2 – Layout Oligo Sets – In this step, you add or remove oligo sets.
Step 3 – Create Library – In this step, you save the library with a status of Draft, which lets you further edit the library, or Submitted, which submits the library to Agilent Manufacturing, prevents further changes, and lets you request a pice quote for the library. Submitting a library does not place an order for that library with Agilent.
Set
the application type to Mutagenesis.
The Home tab of the Mutagenesis application type appears.
In the Library
Wizards pane on the right side of the screen, select Create Mutagenesis Library from Existing
Oligo Sets, then click Next.
The first step of the wizard appears. As you go through the steps of
the wizard, click Next to
go to the next step. To go back to a previous step of the wizard,
click Back (if available).
At any time you can click Close
to close the wizard. eArray allows you to continue the wizard at a
later time.
In this step of the wizard, you enter the name of the library and any optional descriptive information.
In the Library
Name field, type in a name for the library.
The name must be unique for your eArray workgroup. eArray uses the
library name to identify the library in search results and other screens.
If desired, type a description of
the library into the Description
field.
This description appears when the library is viewed or edited within
eArray.
If desired, type any additional
comments into the Comments
field.
Your comments are saved with the library and appear when the library
is viewed or edited within eArray.
Click Next.
The next step of the wizard appears.
In this step of the wizard, you add the desired oligo sets to the library.
Click Add.
A search window opens.
If needed, you can remove an oligo set from the library, or view the oligos in an oligo set.
To remove an oligo set from the library:
To view the oligos in an oligo set:
When you have finished reviewing and editing the library layout, click Next to advance to the next step in the wizard.
In this step of the wizard, you save the library with a status of Draft or Submitted.
To save the library as Draft:
To save the library as Submitted:
See also
Learn about mutagenic oligos and mutagenesis libraries